Did you know? A three Tesla MRI’s magnetic field actually drops to one Tesla 

Agustus 20, 2026 - 03:35
 0  0
Did you know? A three Tesla MRI’s magnetic field actually drops to one Tesla 
Did you know? MRI Magnetic field

Did you know that the three Tesla magnetic field at the core of an MRI machine actually drops to one Tesla as you move away from its center?

An MRI machine does not produce a uniform magnetic field throughout the room. Its strength is highest at the center and decreases with distance, much like the heat from a fire fades the farther you step away. For a three Tesla MRI, this drop is such that the field reaches one Tesla or less right at its immediate periphery.

That is exactly the threshold our Optimax MRI Conditional anesthesia machines are approved for. Designed to operate safely in a magnetic field of one Tesla or less, they were tested directly against a three Tesla MRI, the most demanding benchmark on the market today, in a compatibility study conducted by MED Institute Incorporated of West Lafayette, Indiana. As a result, an Optimax machine can be positioned right next to a three Tesla MRI without compromising either patient safety or imaging accuracy.

MRI Magnetic Field

Have an even more powerful MRI, such as a seven Tesla unit? The same principle still applies. Just confirm with your MRI manufacturer the distance at which the field drops to one Tesla, so you can position your Optimax with the same peace of mind.

Our team is happy to share the results of our MRI compatibility study upon request. Contact your Dispomed representative to learn more.

FAQ: Veterinary Anesthesia and MRI Compatibility

The ASTM F2503-20 standard defines three categories for equipment used in MRI environments: MR Safe (safe in any MRI environment), MR Conditional (safe under specific conditions of field strength, gradient, and specific absorption rate), and MR Unsafe (never to be brought into the MRI room). The Moduflex Optimax is classified MR Conditional at 1 Tesla, which covers the vast majority of current veterinary MRI installations.

Yes, as long as the static magnetic field at the equipment’s positioning point does not exceed 1 Tesla. It is always recommended to confirm this distance with your MRI manufacturer prior to installation.

The compatibility study is available upon request. Contact your Dispomed representative or reach out to us directly through our online form. We will provide you with the complete technical documentation.

Apa Reaksi Anda?

Suka Suka 0
Kurang Suka Kurang Suka 0
Setuju Setuju 0
Tidak Setuju Tidak Setuju 0
Bagus  Bagus 0
Berguna Berguna 0
Hebat Hebat 0
Edusehat Platform Edukasi Online Untuk Komunitas Kesehatan Agar Mendapatkan Informasi Dan Pengetahuan Terbaru Tentang Kesehatan Dari Nasional Maupun Internasional. || An online education platform for the health community to obtain the latest information and knowledge about health from both national and international sources.